Model NO. : HWF80-04N

Type : Electric Holding Furnace

Usage : Ceramic Sintering

Fuel : Electric

Atmosphere : Vacuum/Nitrogen

Effective Chamber Dimensions : 400*400*500mm(W*H*D)

Maximum Temperature : 400°c

Maximum Heating Power : 15kw

Idle Furnace Insulation Power : ≤7.5kw

Temperature Control Accuracy : ±1°c

Thermocouple Type : K-Type

Transport Package : Wooden Packaging

Specification : 1500*1950*1750mm(W*H*D)

Trademark : Chitherm

Origin : China

HS Code : 8514101000

Supply Ability : 50 Sets/Year

Customization : Available

Place Style : Vertical

Range of Applications : Industrial

Contact Now

I. Equipment Name and Model
HWF80-04N Type Dehydrogenation Furnace

II. Application Fields
Decarburization, dehydrogenation, annealing, tempering, degumming, and other heat treatment processes.

III. Technical Specifications and Basic Configuration
The HWF80-04N type dehydrogenation furnace is mainly composed of thermal design, vacuum system, gas inlet design, sealing design, and control system.
Product Model: HWF80-04N Type Dehydrogenation Furnace
Furnace Chamber Effective Dimensions: 400*400*500mm (W*H*D)
Rated Temperature: 350°C (for use in a vacuum environment; the temperature should not exceed 250°C when used in a nitrogen atmosphere)
Maximum Temperature: 400°C (for use in a vacuum environment; the temperature should not exceed 250°C when used in a nitrogen atmosphere)
Heating Element: Stainless steel heating tube for internal heating
Heating Method: Hot air circulation heating
Temperature Measurement Method: Reserved inspection port, can install armored flexible thermocouple for real-time monitoring
Number of Temperature Control Points: Independent temperature control at two points (top and bottom)
Number of Temperature Zones: 2
Maximum Heating Power: 15 kW
Heating Rate: <5 °C/min
Temperature Control Accuracy: ±1°C, with PID parameter self-tuning function
Pressure Rise Rate: 0.67Pa/h
Thermocouple Type: K-type
Cooling Method: Natural cooling with furnace, time from 350°C to room temperature less than 12 hours
Temperature Uniformity: ±5°C (tested with empty furnace at 350°C for 1 hour).

Lab and Research Essential HWF80-04N Precision Muffle Furnace with Effective Chamber Dimensions of 400*400*500mm
Lab and Research Essential HWF80-04N Precision Muffle Furnace with Effective Chamber Dimensions of 400*400*500mm
Lab and Research Essential HWF80-04N Precision Muffle Furnace with Effective Chamber Dimensions of 400*400*500mm
Lab and Research Essential HWF80-04N Precision Muffle Furnace with Effective Chamber Dimensions of 400*400*500mm
Lab and Research Essential HWF80-04N Precision Muffle Furnace with Effective Chamber Dimensions of 400*400*500mm


IV. Delivery List
Table 1 Delivery list
Item Note Qty.
Basic Components Furnace 1 Unit
inspection certificate Certificate of major outsourced components 1 Set
Technical Documents Instructions, technical documents of the major outsourced parts, etc 1 Set
Key Components Heating Element Resistance wire pre-built heating plate 1 Set
Mechanical Pump Busch DRV60 1 Unit
Molecular Pump Zhongke Keyi FF-200 1 Unit
Vacuum Gauge + Regulator Ruibao 1 Set
Oxygen Analyzer Nanoaonai 1 Unit
Touch Screen 1 Unit
Mass Flow Meter Precise Measurement 1 Unit
Temperature Controller Azbil or equivalent brand 1 Set
Thermocouple Type K 3 Pcs
PLC SIEMENS or equivalent brand 1 Unit
Spare Parts SSR 1 PC
Sealing ring Fluororubber 1 Piece

V. Normal Operation Conditions of the Equipment
5.1 Environmental Conditions: Temperature 0~40°C, humidity ≤80%RH, no corrosive gases, no strong airflow disturbance;
5.2 Nitrogen Conditions: Gas source pressure 0.2~0.4Mpa, purity 99.999%, gas consumption 2~6m3/h;
5.3 Conducting Air Source Conditions: Clean, dry, oil-free compressed air, pressure 0.4~0.8Mpa;
5.4 Water Supply Conditions: 0.1~0.3Mpa, clean, non-corrosive, supply flow rate 1~3L/min;
5.5 Ventilation System: Non-contact connection to user's exhaust system, exhaust capacity greater than 10m3/h;
5.6 Floor Requirements: Level, no significant vibration, load-bearing capacity >500kg/m2;
5.7 Power Conditions: Capacity greater than 22kVA, 3-phase 5-wire, voltage 220/380V, frequency 50Hz. Live wires: Yellow, Green, Red; Neutral wire: Blue; Earth wire: Yellow-green;
5.8 Installation Site: 3000mm*2500mm*3000mm (D*W*H), installation area greater than 8m2.


Lab and Research Essential HWF80-04N Precision Muffle Furnace with Effective Chamber Dimensions of 400*400*500mm

Product Tags:

precision muffle furnace with 400x400x500mm chamber

      

lab essential muffle furnace for research

      

vacuum muffle furnace with large chamber

      
Quality Lab and Research Essential HWF80-04N Precision Muffle Furnace with Effective Chamber Dimensions of 400*400*500mm for sale

Lab and Research Essential HWF80-04N Precision Muffle Furnace with Effective Chamber Dimensions of 400*400*500mm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hefei Chitherm Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)